Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
Indian J Ophthalmol ; 2022 Jan; 70(1): 107-111
Article | IMSEAR | ID: sea-224069

ABSTRACT

Purpose: To assess the axial length (AL) measurement failure rate using partial?coherence interferometry (PCI) and swept?source optical coherence tomography (SS?OCT) in dense cataracts. As a secondary outcome, the SS?OCT biometry was compared to immersion ultrasound. Methods: This is a prospective cross?sectional and comparative study. Seventy eyes from 70 patients with dense cataracts were enrolled in this study. Dense cataract was defined according to the Lens Opacities Classification System III (LOCS III) scores equal to or more than NO4, NC4, C4, and P3. The failure rate of AL measurement was evaluated using PCI and SS?OCT. Anterior chamber depth (ACD), lens thickness (LT), and AL measurements obtained by SS?OCT were compared with IUS. Results: AL measurement failure rate with PCI was 68.57% and 21.43% with SS?OCT (P = 0.007). AL measurement was achieved in 69.23% of NO4, 66.6% of P3, and 15.3% of mixed cataracts using PCI, while SS?OCT was achieved in 100% of NO4, NO5, P3, and P5 and 76.9% of mixed cataracts. Cortical cataracts alone did not influence AL measurement. Biometric data of ACD, LT, and AL were statistically different comparing US and SS?OCT with a good correlation of AL. Conclusion: SS?OCT significantly improves the rate of successful AL measurements when compared to PCI in dense cataracts. The LOCS III clinical cut?off for the use of SS?OCT ocular biometry may well be up to P4 and NO5

2.
Rev. mex. oftalmol ; 75(6): 204-206, nov.-dic. 2001. ilus
Article in Spanish | LILACS | ID: lil-326920

ABSTRACT

Los corticoesteroides son comúnmente utilizados en el tratamiento de enfermedades inflamatorias oculares, ya que su concentración a nivel del segmento posterior del ojo es adecuada y se evitan los efectos colaterales de la administración sistémica. Sin embargo la técnica no es inocua y pueden presentarse complicaciones, como perforación del globo ocular con la subsecuente administración del medicamento en la cavidad vítrea o espacio subretiniano. En este artículo, los autores presentan el caso de un paciente en que ocurrió accidentalmente perforación ocular, su diagnóstico, evolución y manejo.


Subject(s)
Humans , Adult , Female , Wounds, Stab , Adrenal Cortex Hormones , Eye , Vitreous Body/injuries , Injections
3.
Rev. mex. oftalmol ; 74(4): 184-8, jul.-ago. 2000. ilus, CD-ROM
Article in Spanish | LILACS | ID: lil-295013

ABSTRACT

Existen varios tipos de lesiones quísticas de la órbita, las cuales presentan características ecográficas comunes como forma redonda u oval, superficie bien delimitada de bordes definidos, y ausencia de vascularidad interna. Dichas lesiones son habitualmente fáciles de diferenciar de los tumores sólidos.


Subject(s)
Orbital Diseases/diagnosis , Teratoma/diagnosis , Hidrocystoma/diagnosis , Dermoid Cyst/diagnosis , Mucocele/diagnosis , Ultrasonography , Orbit/pathology
4.
Rev. mex. oftalmol ; 74(2): 73-5, mar.-abr. 2000. tab, CD-ROM
Article in Spanish | LILACS | ID: lil-295069

ABSTRACT

Los implantes secundarios de lentes intraoculares son importantes para pacientes en los que al realizar cirugía de catarata no se colocó un lente intraocular de primera intención, con la subsecuente dificultad para adaptarse a un lente de contacto y más aún cuando el ojo contralateral es fáquico o pseudofaco. Nosotros revisamos retrospectivamente expedientes del Hospital "Dr. Luis Sánchez Bulnes" de la Asociación Para Evitar la Ceguera, de pacientes que fueron sometidos a cirugía de implante secundario de lentes intraoculares de cámara anterior o posterior en un periodo entre 1989 y 1996, para valorar su capacidad visual final y conocer las posibles complicaciones que existen en estos pacientes. Se describe el tipo de cirugía inicial, el estado en que se encontraba el ojo en el momento del implante secundario, el número de pacientes que estaban rehabilitados visualmente y algunas otras variables clínico-epidemiológicas.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Cataract/therapy , Lens Implantation, Intraocular/methods , Ophthalmologic Surgical Procedures/methods
5.
Rev. mex. oftalmol ; 72(1): 22-5, ene.-feb. 1998. ilus
Article in Spanish | LILACS | ID: lil-252166

ABSTRACT

La amiloidosis representa un espectro de alteraciones que afecta a órganos y sistemas; la fisiopatología involucra una vía metabólica común que resulta en un depósito de proteínas en los tejidos o en múltiple órganos y sistemas. Se presenta el caso de un paciente femenino con una masa blanda en reborde orbitario superior izquierdo, bien delimitada, móvil, con diagnóstico clínico de dacrioadenitis. Se inició tratamiento con prednisolona y sulfas en gotas y ungüento, además de antibiótico por vía oral, sin mostrar cambios en la evolución clínica. Se realizó estudio de ultrasonido ocular y orbitario AO con un equipo Biovisión B-scan-S, observando la presencia de una masa sólida, bien definida, localizada a la glándula lagrimal y con extensión a la porción superior de órbita izquierda. El modo A estandarizado reveló una estructura interna regular y alta reflectividad. El estudio histopatológico reportó una tinción positiva al Rojo Congo y birrefringencia a la luz polarizada con diagnóstico de amiloidosis de la glándula lagrimal. Aunque la amiloidosis de la glándula lagrimal es rara, el estudio de ultrasonido es un método útil en el diagnóstico, aun sin signos clínicos de amiloidosis


Subject(s)
Humans , Female , Adult , Biopsy , Amyloidosis/pathology , Amyloidosis , Lacrimal Apparatus/pathology
6.
Rev. mex. oftalmol ; 71(2): 64-6, mar.-abr. 1997. ilus
Article in Spanish | LILACS | ID: lil-227458

ABSTRACT

En la actualidad una de las cirugías más populares para miopía alta es el procedimiento de Lasik, en la cual, la capa de Bowman es preservada. Nosotros estudiamos 9 ojos de 8 pacientes con ultrasonido biomicroscópico a quienes se les realizó la técnica de Lasik. Todos los pacientes fueron mayores de 20 años de edad, con un equivalente esférico promedio de -9.69 dioptrías. A la exploración con ultrasonido biomicroscópico las características de la córnea fueron similares tanto en el examen pre y postoperatorio, el grosor corneal promedio preoperatorio fue de 562 micras y en el post operatorio de 470 micras, la profundidad de la cámara anterior no presentó cambios significativos. La profundiad de la ablación promedio calculada en el preoperatorio fue de 90 micras y en post operatorio fue de 74 micras


Subject(s)
Humans , Male , Female , Adult , Ultrasonography/instrumentation , Myopia/surgery , Myopia , Anterior Chamber , Laser Therapy , Endothelium, Corneal
SELECTION OF CITATIONS
SEARCH DETAIL